Sinusoid SS1 single and three phase digital electeical meter

Category:

Application:

SINUSOID SS1 series programmable digital display electrical meters replaces the single quantity analogue panel meters and measures important electrical system parameters such as AC Voltage (single phase and three phase) and AC Current (single phase and three phase) on 1-phase, 2-wire networks, 3-phase, 3-wire networks as well as 3-phase, four-wire networks.
SINUSOID SS1 series digital display meter can be used in various installations such as the ones in residential, commercial, industrial, mining, public facilities, intelligent building controls and other related installations.

Features:

  • Quick and easy installation
  • True RMS measurement
  • Bright LED display options:
    • 1 line, 4 digits (up to 9999)
    • 3 lines, 4 digits (up to 9999)
  • On-site programmable Current Transformer (CT) and Potential Transformer (PT) ratios
  • User-selectable external CT secondary (1A/5A)
  • Rated voltage: 100VAC/400VAC
  • Four function keys for quick access to desired screens
  • Configurable for 1-phase, 2-wire, 3-phase, 3-wire, or 3-phase, 4-wire setups
  • Standard auxiliary power: 220VAC (default) or 85-265V AC/DC wide range
  • Compact design, even with optional features
  • Optional RS485, MODBUS-RTU protocol
  • Optional relay output
  • Optional pulse output
  • Optional analogue output
  • Optional switch input

Parameters

  • Basic Parameters         V, I, Hz (As per choice)
  • Power Parameters
  • Energy Parameters
  • Demand Parameters
  • Power Quality Parameters         PF (As per choice)

Wiring/Connection

  • Parameter: 1-phase, 2-wire / 3-phase, 3-wire / 3-phase, 4-wire

Voltage (Input Characteristics)

  • Rated Voltage: 100VAC, 400VAC, other
  • Overload: Continuous 1.2 times, instantaneous 2 times
  • Power Consumption: <0.1VA
  • Impedance: ≥500kΩ
  • Accuracy: 0.5%
  • PT Secondary Values: 100VAC L-L or 400VAC L-L
  • PT Primary Values: On-site programmable up to 0001V-9999V

Current (Input Characteristics)

  • Rated Current: 5A / 1A AC RMS
  • Overload: Continuous 1.2 times, instantaneous 2 times
  • Power Consumption: <0.4VA (each phase)
  • Impedance: ≤2mΩ
  • Accuracy: 0.5%
  • CT Secondary Values: On-site programmable 5A / 1A
  • CT Primary Values: Programmable from 0001A up to 9999A (for 5A / 1A)

Power Supply

  • Frequency: 40-65Hz, ± 0.1Hz
  • Display: Digital (Seven-segment display)
  • Auxiliary Power Supply: 220VAC (default) or 86-265V AC/DC (optional)
  • Power: ≤5VA

Communication

  • Digital Interface: RS485 (optional)
  • Protocol: MODBUS-RTU (optional)
  • Communication Baud Rate: 2400-19200
  • Data Length: 8-bit, no parity

Output

  • Analog Output: 4-20mA transmission (optional), programmable setting of transmission items with 1% accuracy
  • Relay Output: Programmable remote control and alarm relay output
    • Capacity: 250VAC 3A/30VDC
    • Programmable setting of alarm items and corresponding values or remote control

Input

  • Analog Input: Telemetry Switch into Test-Passive Dry Node Input
  • Programmable associated relay output

Ambient Temperature

  • Working Environment: -10 to 55°C
  • Storage Environment: -20 to 75°C

Applicable Standards

  • Standards: IEC 61010, IEC 60529, IEC 61326

Enclosure

  • Front: IP50
  • Back: IP20

 

 

 

Ordering Summary


SS1

  • Auxiliary Supply
    • Standard AC 220V, 1ph
    • Universal AC/DC 85^250V
  • Dimensions
    • 120×120
    • 96×96
    • 80: 80×80
    • 72: 72×72
    • 48:48×48
    • 80:80×80
    • 9648: 96×48
  • Function code
    • U: Voltage
    • I: Current
    • F: Frequency
    • PF: Power Factor
  • Phase
    • 1: Single Phase
    • 3: Three Phase
  • D: Digital Display
Scroll to Top